Engine accessories:

  • Heavy-duty air filter
  • Coolant heater
  • Lubricant oil heater
  • Fuel and Water Separator
  • Lube oil rotary pump

Alternator And Accessories:

  • Leroy somer/stamford
  • Anti condensation heater
  • PMG + AVR ◇ Double bearing
  • alternator High voltage ______kV
  • RTDs for Bearing and winding

Cooling System:

  • 55 degree Radiator
  • Remote Radiator

Control System:

  • AMF
  • Parallel
  • Practical type in low temperature environment
  • Control Screen Heater
  • Remote Annunciators
  • Other(ComP, DEIF)

Circuit Breaker:

  • 3/4 poles
  • Fixed/handcart type
  • Electric mechanism

Automatic Transfer Switch (ATS):

  • ATS cabinet
  • Contractor type ATS
  • Motorized changeover type ATS

Start Battery:

  • Nickel-cadmium battery
  • Maintenance-free battery
  • Battery charger and selector switch
  • Charging current meter

External Fuel Tank:

  • Single /double wall fuel tank (500-5000 L)
  • Fuel Transfer pump

Exhaust Muffler:

  • Residential grade
  • Critical grade
  • Hospital grade

Available for voltages :

  • 400/230V, 480/277V, 380/220V, 440/254V, 416/240V,220/127V, 208/120V
Rent Now

Standard Specifications:

  1. 1- Prime Rating:Unlimited hours usage, with an average
    load factor of 80% over each 24 hour peri-
    od. 10% overload is available for 1 hour in
    every 12 hours operation. 0 overload is
    permitted on standby power.
  2. 2- Standby Rating:Limited to 500 hours annual usage, with an
    average load factor of 80% of the pub-
    lished standby power rating over each 24
    hour period. Up to 300 hours of annual
    usage may be run continuously. No over-
    load is permitted on standby power.
  3. 3- Engine:Perkins, including air filters, fuel filters,
    oil filter, starting motor and charging alter-
    nator etc.
  4. 4- Alternator Type:brushless AC alternator
  5. 5- Radiator:50°C, fan protective shroud
  6. 6– Fuel Tank:Capacity of fuel tank is for 8-10 hours running
    Built in fuel tank up to 800 kVA
  7. 7- Circuit Breaker:3 pole LS MCCB
  8. 8– Control system alarms:
    • Over and Under Speed
    • Low and High Battery Volt.
    • Start and Stop Failure
    • Over Current
    • Under / Over Generator Voltage
    • Low Oil Pressure
    • Emergency stop
    • High engine temperature
  9. 9– Warranty policy:
    • AQT Generator products has a warranty for 12 Months or 1000 hours whichever occurs first against any manufacturing defects
    • Wearing parts (filters), incorrect man made operation, maintenance failures are excluded from the warranty policy

Acoustic Enclosure Specifications:

Enclosure Type Acoustic & Weather Proof
Drainage Provision Fuel and Water Drainage
Transportation Tested Single Point Lifting
Facility & Forklift Pockets
Ingress Protection Rating IP 23
Lifting ISO Standard Lifting
Canopy RAL Color TAL 9010
Base frame RAL Color RAL 9011
Noise Pressure level @ 7m 70db(A) @ 7mt

Output Rating:

PRIME: STANDBY:
50 Hz—1500 Rpm 400 V, 3ph
135 kVA 108 kW
150 kVA 120 kW
60 Hz—1800 Rpm 480 V, 3ph
152 kVA 122 kW
169 kVA 135 kW
ENGINE SPECIFICATIONS
Engine Make PERKINS
Engine Model 1106A-70TAG1
No. of Cylinders 6 vertical in-line
Cycle 4 Strokes
Aspiration Turbocharged
Cooling Method Water cooled
Governing Type Electronic
Governing Class G2 – ISO 8528 Part 1
Compression Ratio 18.2:1
Displacement 7.01 L
Bore/Stroke 105 x 135 mm
Dynamic Charging Alternator 55AMP, 12V
ALTERNATOR SPECIFICATIONS
Alternator Make Leroy Somer | STAMFORD
Alternator Model TAL-044-H | UCI274E
Number of Poles 4
Number of Winding Leads 6
Type of Bearing Single Bearing
Insulation Class – Temp Rise Cont. H – 125/40̊ C̊
Ingress Protection Rating IP 23
Excitation System Self Excited
AVR Model R120
Comply with Standards
ISO 3046, BS 5514, DIN 6271, NEMA-MGI, DIN EN, BS 5000, IEC 60034,IEC 60947-2
Alternator Operating Data
Over speed 2250 rpm
Voltage Regulation ± 1%
Harmonic Coefficient THF < 2%
Tel. influence TIF < 50
Cooling air flow 0.25 m3/ Sec

Engine:

Perkins heavy duty high performance industrial type diesel engine.

COOLING SYSTEM
Total Coolant Capacity (L) 21 L
Cooling Fan Air Flow 182 m3/ min
Radiator Fan Load 4.4 kW
Heat Radiation to Room (PRP) 12.5 kW
Heat Radiation to Room (ESP) 15.3 kW
LUBRICATION SYSTEM
Oil Filter Type Spin-On Full Flow
Total Oil Capacity 16.5 L
Oil Type API-CH-4 or ACEA E5
EXHAUST SYSTEM
Muffler Type Industrial Grade
Max. Back Pressure 6 kPa
Exhaust Gas Flow (PRP/ESP) 20.75 /22.6 m3/ min
Exhaust Gas Temperature < 5760C
FUEL SYSTEM
Recommended Fuel Class A2 Diesel
Fuel Consumption Standby 33.8 L/hr
Fuel Consumption 100% PRP 30.2 L/hr
Fuel Consumption 75% PRP 22.7 L/hr
Fuel Consumption 50% PRP 15.9 L/hr
AIR SYSTEM
Air Filter Type Dry Element
Combustion Air Flow (PRP) 7.64 m3/min
Combustion Air Flow (ESP) 8.09 m3/min
Max Air Filter Intake Restriction 5 kPA

Control System:

  • Large back-lit text display
  • Multiple display languages
  • DSENET expansion compatible
  • Data logging facility
  • Fully configurable via PC using USB communication
  • Front panel configuration
  • Efficient power save mode
  • 3 phase generator sensing
  • Accumulated power monitoring (kWh, kVA h, kVAr h)
  • Generator/load current monitoring and protection (kW)
  • Breaker contol via fascia buttons
  • Fuel and start outputs, configurable using can
  • 4 configurable DC outputs
  • 4 configurable analogue/digital inputs
  • Automatically transfers between mains (utility) and generator
  • Increased input and output expansion capability via dsenet
  • IP65 rating (with optional gasket) offers increased resistance to water ingress
  • Digital inputs; Analogue Inputs

Dimensions:

Type Length
(mm)
Width
(mm)
Height
(mm)
Fuel Tank
( L )
Weight
(KG)
OPEN 2500 775 1425 280 1325
CLOSED 3200 1100 1790 280 1975

Electrical Load Calculator

Lights

20W Tubelight
60W Light Bulb
100W Light Bulb
20W Energy Saver

Air Fans

21" LCD
DVD Player
Home Theater
Desktop PC
Laptop
Refrigerator
Freezer

Air Conditioners

1.5 Ton
2 Ton
2.5 Ton
3 Ton
3.5 Ton
4 Ton
4.5 Ton
5 Ton

Appliances

Fans
Air Coolers